PLC

3401 TRICONEX

Nominal output voltage 24 VDC Specified operating voltage range 15 to 30 VDC Absolute maximum output voltage 33 VDC Absolute maximum reverse input voltage – 0.6 VDC< 4.8 A, self limiting 3.0 A, typical> 0.7 A, self limiting 1.5 A, typical value Field alarm Field power loss, Output point short circuit On or Off Loop back threshold 0 – 5 VDC=Closed area 6 – 14 VDC=Transition area 15 – 30 VDC=Open area Load leakage (off state)< 1 mA Diagnostic Burr Duration< 2 milliseconds, maximum 500 Ps, typical on voltage drop< 1.0 VDC 1.5 A loopback scan time all 16 points< 1.0 ms functional ground to protective ground isolation 500 VDC, minimum functional ground to functional ground (logic) isolation 800 VDC, maximum

Get A Quote
Contact Us

3401 TRICONEX

Nominal output voltage 24 VDC Specified operating voltage range 15 to 30 VDC Absolute maximum output voltage 33 VDC Absolute maximum reverse input voltage – 0.6 VDC< 4.8 A, self limiting 3.0 A, typical> 0.7 A, self limiting 1.5 A, typical value Field alarm Field power loss, Output point short circuit On or Off Loop back threshold 0 – 5 VDC=Closed area 6 – 14 VDC=Transition area 15 – 30 VDC=Open area Load leakage (off state)< 1 mA Diagnostic Burr Duration< 2 milliseconds, maximum 500 Ps, typical on voltage drop< 1.0 VDC 1.5 A loopback scan time all 16 points< 1.0 ms functional ground to protective ground isolation 500 VDC, minimum functional ground to functional ground (logic) isolation 800 VDC, maximum

Nominal output voltage 24 VDC Specified operating voltage range 15 to 30 VDC Absolute maximum output voltage 33 VDC Absolute maximum reverse input voltage – 0.6 VDC<4.8 A, self limiting 3.0 A, typical>0.7 A, self limiting 1.5 A, typical value Field alarm Field power loss, Output point short circuit open loop or closed loop return threshold 0 – 5 VDC=closed area 6 – 14 VDC=transition area 15 – 30 VDC=open area load leakage (closed state)<1 mA Diagnostic burr duration<2 milliseconds, maximum 500 Ps, typical open loop voltage drop<1.0 VDC 1.5 A loop back scan time All 16 points<1.0 ms Functional ground to protective ground Isolation 500 VDC, minimum functional ground to functional ground (logical) Isolation 800 VDC, maximum

RELIANCE ELECTRIC 86466-92T 8646692T RECTIFIER

RELIANCE ELECTRIC 800082-1R NSFP 8000821R

RELIANCE ELECTRIC 801429-5SE USPP 8014295SE

RELIANCE ELECTRIC 0-54339-6 USPP 0543396

Reliance Electric DDS-SABS5,32416,32416-005A(NEW)

Reliance Electric 86466-91RC Rectifier Stack-NIB

RELIANCE ELECTRIC 75HP 460V N1 VFD W/N3R ENCLOSURE

RELIANCE ELECTRIC Input Module Analog 16 Channel 61C544

RELIANCE ELECTRIC SA3000DC070 USPP SA3000DC070

RELIANCE ELECTRIC 615055-1R USPP 6150551R

Tags: ,
Scroll to Top