PLC

1734-IB4 AB

technical specifications

Manufacturing region * Singapore

Type PLC input module

Manufacturer: Allen Bradley/Rockwell Automation

Input: 1 group of 4 people, sinking

Enclosure Type Rating: Open (None)

Minimum conduction voltage: 10 VDC

Nominal on-state voltage: 24 VDC

Maximum on-state voltage: 28.8 VDC

Network/module status: 1 green/red indicator

Input status: 4 yellow indicators

Maximum POINTBus current: 75 mA at 5 VDC

Maximum heat dissipation: 3.4 British thermal units (BTU) per hour

Isolation voltage: 50 V (continuous)

Nominal field power supply voltage: 24 VDC

Field power supply voltage range: 10… 28.8 VDC

Dimensions (approximately): 56 x 12 x 75.5 mm (2.2 x 0.47 x 2.97 inches)

Weight (approximately): 31.8 grams (1.12 ounces)

Operating temperature: – 20 to 55 degrees Celsius

Get A Quote
Contact Us

1734-IB4 AB

The 1734-IB4 has an isolation voltage of 50 volts (continuous) and has a reinforced insulation type. The nominal field power supply voltage is 24 VDC, and the field power supply voltage range is 10… 28.8 VDC. It measures approximately 56 x 12 x 75.5 mm, or 2.2 x 0.47 x 2.97 inches. This hardware has an open housing type rating (none). The device weighs approximately 31.8 grams, or 1.12 ounces. Environmental specifications include operating temperatures between – 20 and 55 degrees Celsius and non operating temperatures between – 40 and 85 degrees Celsius. Relative humidity is 5% to 95%, non condensing. The vibration is 5 g @ 10… 500 Hertz, in accordance with IEC 60068-2-6, while the working shock is 30 g (in accordance with IEC 60068-2-27); The non working impact is 50 g, in accordance with IEC 60068-2-27 standards.

Allen Bradley and Rockwell Automation’s 1734-IB4 is a Point I/O input module. It has an open housing type rating and a set of 4 submerged inputs. 1734-IB4 has a minimum on state voltage of 10 VDC and a nominal on state voltage of 24 VDC. The maximum on-voltage of the module is 28.8 VDC. Other specifications for this hardware include one green/red indicator for network and module status, and four yellow indicators for input status. The module has a maximum POINTBus current of 75 mA at 5 VDC and a maximum thermal dissipation of 3.4 British thermal units (BTUs) per hour.

technical specifications

Manufacturing region * Singapore

Type PLC input module

Manufacturer: Allen Bradley/Rockwell Automation

Input: 1 group of 4 people, sinking

Enclosure Type Rating: Open (None)

Minimum conduction voltage: 10 VDC

Nominal on-state voltage: 24 VDC

Maximum on-state voltage: 28.8 VDC

Network/module status: 1 green/red indicator

Input status: 4 yellow indicators

Maximum POINTBus current: 75 mA at 5 VDC

Maximum heat dissipation: 3.4 British thermal units (BTU) per hour

Isolation voltage: 50 V (continuous)

Nominal field power supply voltage: 24 VDC

Field power supply voltage range: 10… 28.8 VDC

Dimensions (approximately): 56 x 12 x 75.5 mm (2.2 x 0.47 x 2.97 inches)

Weight (approximately): 31.8 grams (1.12 ounces)

Operating temperature: – 20 to 55 degrees Celsius

Notifier CPU Board CPU-3030D

Agilent/HP E4970-66501-4396B,4395A A1 CPU Board

GIDDINGS&LEWIS 501-03761-02 CPU BOARD TESTED

ALLEN BRADLEY 8600 1880L(CPU BOARD)OSAI OS5001V

HP MSL2024 LIBRARY LT02 CPU BOARD/NETWORK INTERFACE

HP 9000 HP9000 E45 CPU Board A2051-66541 A3131-60001

LOT OF TWO MOTOROLA MVME 6000BC CPU BOARD

Tags: ,
Scroll to Top