PLC

FBM204 FOXBORO

describe

FBM204 0 to 20mA input/output includes four 20mA DC analog input channels

And four 20 mA DC analog output channels,

Each input channel accepts analog sensor inputs, such as 4 to 20 mA transmitters

Or self powered 20 mA source. Each output channel drives an external load and

Generate 0 to 20mA output, with input/output isolated from other channels and ground currents

FBM204 execution will

The electrical input/output signals from field sensors are connected to the optional redundant fieldbus for signal conversion. FBM204

Execute a simulated 1/O application that provides the following

Configurable options: transition time, fail safe configuration (hold/fall back), and

Analog output fault safe fallback data (based on each channel), fieldbus module

(FBM) can be changed to execute distributed PIDA (DPIDA) applications to

Provide a fast control loop that operates within it.

FBM204 is electrically compatible with standard HART signals.

Get A Quote
Contact Us

FBM204 FOXBORO

FOXBORO FBM204

Four 20 mA DC analog input channels and four 20 mA DC analog output channels, each

The channels are isolated and independent.

Input/output range

(per channel)

0 to 20.4mAdc (nominal)

Input channels (four) · Accuracy (including linearity):

± 0.03% of span

·Precision temperature coefficient:

±50 ppm/℃

·Input signal A/D conversion:

Each channel uses an independent Siama Delta converter to perform A/D signal conversion

·Input channel impedance:

61.5 Ω nominal

·Integral period:

Software configurable

·Common mode suppression:

>100 db @ 50 or 60Hz

。 Normal mode suppression:

>95 db @ 50 or 60Hz

。 Field equipment wiring distance:

The maximum distance between on-site equipment and FBM is compliant

A function of voltage (20.2Vdc, 20.4mA input), wire gauge, and field device voltage drop.

·Loop power protection:

Each channel is characterized by inter channel current isolation, current limiting, and

Stabilized voltage, all analog inputs are limited by their design to less than 30 mA, if

The current limiting circuit is short circuited and the current is limited to around 100mA

describe

FBM204 0 to 20mA input/output includes four 20mA DC analog input channels

And four 20 mA DC analog output channels,

Each input channel accepts analog sensor inputs, such as 4 to 20 mA transmitters

Or self powered 20 mA source. Each output channel drives an external load and

Generate 0 to 20mA output, with input/output isolated from other channels and ground currents

FBM204 execution will

The electrical input/output signals from field sensors are connected to the optional redundant fieldbus for signal conversion. FBM204

Execute a simulated 1/O application that provides the following

Configurable options: transition time, fail safe configuration (hold/fall back), and

Analog output fault safe fallback data (based on each channel), fieldbus module

(FBM) can be changed to execute distributed PIDA (DPIDA) applications to

Provide a fast control loop that operates within it.

FBM204 is electrically compatible with standard HART signals.

FBM204 has a sturdy extruded aluminum casing that can be

The circuit provides physical protection. According to ISA standard S71.04, enclosures designed specifically for installing FBM are available in various levels

Environmental protection, up to harsh environments.

Visual indicator module

Front integrated red and green light emitting diodes (LEDs)

Provide visual status indication of FBM function.

Easy to disassemble/replace

This module is installed on the Compact 200 series substrate, and the two screws on the FBM will

Fix the module to the substrate.

The module can be removed/replaced without the need to remove on-site equipment terminal cables, power or communication cables.

Fieldbus communication

The fieldbus communication module or control processor is connected to the

The redundant 2 Mbps module fieldbus used by FBM. FBM acceptance

Communication from any path (A or B) of the 2 Mbps fieldbus, if one path

Unsuccessful or system level switch, module will continue

Communicate through active paths.

Modular base plate installation

The module is installed on a modular base plate mounted on DIN rails,

Can accommodate up to four or eight FBMs. Modular base plate adopts DIN rail installation or rack installation, including for redundant fieldbus and redundancy

Signal connectors for independent DC power supply and termination cables,

characteristic

。 Four 20mA DC analog input channels

Four 20 mA DC analog output channels

。 Each input and output channel is electrically isolated. Rugged design suitable for G3 grade (harsh) environments

Execute simulated 1/O application, provide conversion time and

Configurable options for rate of change restrictions

。 High accuracy achieved through sigma delta data conversion for each channel

Terminal assembly (TA) for connecting field wiring to Compact FBM204 locally or remotely

。 TA is used in conjunction with the output bypass station to maintain output during maintenance operations

。 Internal and/or external loop powered transmitters for each channel

Layer 3 terminal components for. Support the use of dry DPIDA control blocks for high accuracy. In order to achieve high accuracy, this module integrates Sama Delta data conversion on the basis of each channel, providing a new analog input read every 25 milliseconds

Number, as well as a configurable integration period, to eliminate any process and/or noise and power line frequency. At each time period, FBM converts each analog input into digital values,

 

Scroll to Top