PLC

FBM216B P0927AJ FOXBORO

Redundant HART communication input module

Full Description: Foxboro FBM216B P0927AJ Redundant HART Communication Input Module FBM216b HART Communication Redundant Input Interface Module contains eight independent isolated input channels. It supports any combination of standard 4 to 20 mA devices and HART devices (signals are electrically compatible).

Get A Quote
Contact Us

FBM216B P0927AJ FOXBORO

The Jingjiao FBM216b HART communication redundant input interface module includes eight independent input channels with high isolation. It supports any combination of standard 4 to 20mA devices and HART devices (signals are electrically compatible). Pair of module combinations

Together to provide redundancy at the Field Bus Module (FBM) level, the field inputs are connected to a common termination component (see Figure 1). In this configuration, one Compact FBM216b is the Master and the other is the Tracker

Compact FBM216b can be used as a HART communication field device host, enabling Foxboro DCS to request and receive two digital messages per second from the field device. Message passing capability can be used to support HART universal, universal, and device

Specific commands, but cannot support burst communication mode. These commands are implemented using Foxboro DCSField Device Expert for HART. For detailed information, please refer to the HART device control and 1/0 field device experts

(PSS 41S-10FDMHRT)。 Compact FBM216b provides a separate isolated power supply to power each of the eight channels. Optionally, the channel of the module can be powered by an external power source. However, when two or more pass through

When using a common external power supply, a Cable Balun module is required to help prevent crosstalk in the HART communication channel.

Full Description: Foxboro FBM216B P0927AJ Redundant HART Communication Input Module

The FBM216b HART communication redundant input interface module includes

Eight independent isolated input channels. It supports any combination of standard 4 to 20mA

Device and HART device (signal is electrically compatible).

A pair of modules are combined to provide redundancy on the fieldbus module (FBM)

Horizontally, the field input is connected to a common termination component, one FBM216b being the Master and the other being the Tracker.

FBM216b can be used as a host for HART communication field devices, enabling

FoxboroMDCS requests and receives two digital messages per second from the site

Device, messaging capability can be used to support HART universal

Common practices and device specific commands, but it cannot support bursts

Communication methods.

Redundant HART communication input module

Full Description: Foxboro FBM216B P0927AJ Redundant HART Communication Input Module FBM216b HART Communication Redundant Input Interface Module contains eight independent isolated input channels. It supports any combination of standard 4 to 20 mA devices and HART devices (signals are electrically compatible).