IPM02 P0904HA FOXBORO I/A Series Industrial Power Module 2 Features: 100/120/220/240 VAC Optional Input 39 V DC Output Status Indicator Schneider Electric/Invensys/Foxboro P Series I/A Series Industrial Power Module Features 100/120/220/240 VAC Optional Input, 39 VDC Output and Status Leadership.

 

IPM2-P0904HA FOXBORO

describe

FOXBORO IPM2-P0904HA

1.2 Specifications

The following specifications describe the

Published operating characteristics of the series power supply:

Package size

Size 1- Up to 20kW nominal output

Size 2- Up to 30kW nominal output

Size 3- Up to 60kW nominal output

Size 31/2- nominal output up to 90kW

1.2.1 AC Input:

460V ± 10% 60Hz standard, or specified optional voltage.

IPM02-P0904HA FOXBOROI/A Series Industrial Power Module 2

characteristic:

100/120/220/240VAC optional input

39V DC output

Status indicator light

Schneider Electric/Innvensys/FoxboroP series 1/A industrial power module with 100/120/22/24VAC optional input, 39VDC output, and status LED

Adjustment:

Voltage mode – for

The change in line voltage or load current within the rated range of the power supply will not exceed the change in output voltage

0.1% of the maximum rated current.

Current mode – for

The change in line voltage or load voltage within the rated range of the power supply will not exceed the change in output current

0.1% of the maximum rated current.

On devices where the percentage of voltage or current ripple exceeds the specified value, due to the impact of this ripple on the measurement

The impact of regulations seems to be decreasing. 1.2.3 Stability: After preheating, the output voltage or current remains within 0.05% for 8 hours, with constant external influence. 1.2.4 Ripple: Grounded at the positive or negative output terminal and 100% output

The output changes caused by load changes between 50% and 100% of the limit value are usually

Restore to within 1% of its final value within 200 milliseconds.

Temperature coefficient:

The output voltage TC is 0.02%/℃ of the maximum rated value.

The output current TC is 0.03%/℃ of the maximum rated value.

Working temperature:

0 ° C to 50 ° C at

At an ambient temperature of 71 degrees Celsius, the current linearly decreases to 50% of the rated value of the meter.

Storage temperature:

-40 degrees Celsius to+85 degrees Celsius.

Instrument:

Voltmeter, ammeter, power indicator, input phase indicator and

Work mode indicator light.

Control:

Circuit breaker switch control, start/stop button switch, voltage

And current control.

A200 Overbed Protection Adjustment for Units Equipped with OVP Option

Cooling:

All devices are equipped with fan cooling and constant temperature protection. Air enters from the front of the equipment

From behind