1746-A13 AB

1746-A13 AB

Technical specifications for 1746-A13

Manufacturer Rockwell Automation

Weight 1.9 kg (4.2 lb)

Installation Clearance Top Clearance:>15.3 cm (6.0 inches) Side Clearance:>10.2 cm (4.0 inches)

Relative humidity 5 to 95% (non condensing)

Storage temperature – 40 ° C to+85 ° C (- 40 ° F to+185 ° F)

Operating temperature 0 ° C to+60 ° C (+32 ° F to+140 ° F)

Number of mounting plates eight (8)

Physical dimensions 50.2 x 17.1 x 14.5 cm (20.1 x 6.8 x 5.8 inches)

Backplane current 5.1V DC @ 10A; 24V DC @ 2.88A

Slot Number of Three (13) slots

1746-A13 AB

About 1746-A13

Allen Bradley 1746-A13 is a thirteen (13) slot chassis from the SLC500 programmable logic controller (PLC) platform. This chassis provides backplane connections and enclosures for the central processing unit (CPU), I/O, communication, and dedicated modules, as well as system power supplies.

1746-A13 comes with eight (8) installation tabs for installing the chassis directly onto the sub panel of the enclosure. When installing a module to a subpanel, the appropriate screws are M4 or M5 (# 10 or # 12) Phillips screws. The recommended minimum installation clearance is 15.3 cm (6.0 inches) at the top and>10.2 cm (4.0 inches) at the side. When used with rack extension cables such as 1746-C7, the minimum spacing is 7.7 to 10.2 centimeters (3.0 to 4.0 inches).

The physical dimensions of the 1746-A13 are 50.2 x 17.1 x 14.5 centimeters (20.1 x 6.8 x 5.8 inches) and weigh 1.9 kilograms (4.2 pounds). The electronic circuit carrying the backplane connection can provide a maximum backplane current of 10A @ 5.1 VDC and 2.88 A @ 24 VDC. The chassis is designed to operate in an environment with a temperature range of 0 ° C to+60 ° C (+32 ° F to+140 ° F). In addition, the spare 1746-A13 chassis can be stored in a temperature range of – 40 ° C to+85 ° C (- 40 ° F to+185 ° F), relative humidity of 5-95%, non-condensing.

1746-A13 is a UL listed industrial control device that has been certified in the United States and Canada, meets CE standards, and complies with the Australian Wireless Communications Act. It is suitable for installation in environments identified as Class I, Division 2, Groups A, B, C, D, or non hazardous locations.

Technical specifications for 1746-A13

Manufacturer Rockwell Automation

Weight 1.9 kg (4.2 lb)

Installation Clearance Top Clearance:>15.3 cm (6.0 inches) Side Clearance:>10.2 cm (4.0 inches)

Relative humidity 5 to 95% (non condensing)

Storage temperature – 40 ° C to+85 ° C (- 40 ° F to+185 ° F)

Operating temperature 0 ° C to+60 ° C (+32 ° F to+140 ° F)

Number of mounting plates eight (8)

Physical dimensions 50.2 x 17.1 x 14.5 cm (20.1 x 6.8 x 5.8 inches)

Backplane current 5.1V DC @ 10A; 24V DC @ 2.88A

Slot Number of Three (13) slots

Scroll to Top