190065A-01-01-01-00-00 BENTLY

Manufacturer:Bently Nevada

Product number:1900/65A-00-01-01-01-00

Product Type:1900/65A Universal Device Monitor

Made in the United States

Certificate of origin(COO)can be added

Power option:00=18 to 36 Vdc

Display option:01=Additional display(without cable)

Installation option:01=DIN rail installation(see Figure 1)

Approval option:01=Multiple approvals.For specific certifications,please refer to the Hazardous Area Certification section.

Communication option:00=none

Monitoring module size(length x width x height):19.69 cm x 14.94 cm x 7.44 cm

Shipping weight:8 kilograms

Get A Quote
Contact Us

190065A-01-01-01-00-00 BENTLY

Channel number (14) being configured for 1900/65A-01-01-00-00.

a slot

The position of the monitor in the 3500 rack (12 to 15).

rack type

Identify the type of rack interface module installed in the rack (standard

Or TMR).

Enable

Direct

Due to changes in the position of thermal growth relative to the axis

Housing. This value may be displayed in inches or millimeters. this

Proportional values support center zero and non center zero full scale

Range.

disparity

1900/65A-01-01-01-00-00 Physical distance between the surface of the proximity probe tip and the probe

Observed surface. The distance is expressed in voltage. standard

According to the polarity convention, reducing the gap leads to an increase

(Reduce load) Output signal. When the channel or

The proportional value is bypassed or defeated (for example, when a problem

Occurring on the transducer). 1900/65A-01-01-00-00-00 The selected value can be between

Minimum and maximum full-scale range values. Only available values

From recorder output, communication gateway, and display

When the interface module is clamped to the specified value, the proportion

Invalid value.

Recorder output

The proportional value of the channel sent to the 4 to 20mA recorder.

The recorder output is proportional to the measured value

Channel full scale range. An increase in the proportional value will

Displaying high gear on the bar chart display will cause

Currently outputting from the recorder. If the channel is bypassed, the output will

Be clamped to the selected clamping value or 2mA (if 2mA is clamped)

Selected)

Manufacturer:Bently Nevada

Product number:1900/65A-00-01-01-01-00

Product Type:1900/65A Universal Device Monitor

Made in the United States

Certificate of origin(COO)can be added

Power option:00=18 to 36 Vdc

Display option:01=Additional display(without cable)

Installation option:01=DIN rail installation(see Figure 1)

Approval option:01=Multiple approvals.For specific certifications,please refer to the Hazardous Area Certification section.

Communication option:00=none

Monitoring module size(length x width x height):19.69 cm x 14.94 cm x 7.44 cm

Shipping weight:8 kilograms