350033-01-00 BENTLY
Manufacturer: Bently Nevada
Product No.: 3500/33-01-00
Product type: 16 channel relay module
Made in the United States
Certificate of Origin (COO) can be added
Output module: 01=16 channel relay output module
Agency Approval Option: 00=None
Dimensions (L x W x H): 24.20 cm x 2.44 cm x 24.10 cm
Weight: 0.70 kg
Shipping weight: 2 kg
The advantages of using safety PLC/DCS and safety net include:
Greater integration and flexibility in mechanical control
When the standard control layer is intelligent, it can perform better and easier fault diagnosis
Faster and more convenient maintenance
Reduce installation, debugging, and reconfiguration costs
Bently module 3500/33-01-00 (149986-01+149992-01)
The 3500/33 16-Channel Relay Module is a full-height module that provides an output of 16 relays. Any number of 16 channel relay modules can be placed in any slot on the right side of the frame interface module. Each output of the 16-channel relay module can be independently programmed to perform the required voting logic.
Each relay applied to a 16 channel relay module has an “alarm drive logic”. Ths alarm drive logic can be programmed using AND and OR gates, and can utilize alarm inputs (warning or danger), non OK, or standalone PPL provided by any monitor channel or combination of monitor channels in the framework. The alarm drive logic application framework configuration software programming can meet the special needs of applications.
spare part
149986-01,Spare 16-Channel Relay Control Module
149992-01,Spare 16-Channel Relay Output Module
04425545,Grounding bracelet(single purpose)
162291-01,16-Channel Relay Module Manual
00580453,connector,internal terminal,16 bit,green
3500/33-01-00
3500/33-01-CN
QT500/QT510 This is a verified***turbine flowmeter,and its connecting internal threads comply with ISO228 standards.There are two signal output methods:digital signal output(frequency,rectangular wave signal)and analog signal output(4…20mA).
This turbine flowmeter has a factory calibrated viscosity of 30 cSt,and other viscosities can be provided as calibration viscosities.You can also customize the version of two-way traffic detection,but you cannot detect the flow direction.
Operating principle Turbine speed is proportional to flow
NIB Allen Bradley Powerflex 700 20BD014A0AYNAND 10HP
ALLEN BRADLEY POWERFLEX 700S 20DD8P0A0EYNANNNN**NICE**
Allen Bradley 20BD022A0AYNANC0 PowerFlex 700 15HP Test
ALLEN BRADLEY POWERFLEX 700 20B D 2PI A3 AYNANC0
Allen Bradley Powerflex 700 20BD027A3NYNARB0/A 20HP
NEW Allen Bradley 10HP Powerflex 700 20BB028A3AYNBNB0