PLC

350050 BENTLY

Speed Input:
The 3500 Tachometer will support0.0039 – 255 events per revolutionwith a maximum full scale rangeof 99,999 rpm and a maximuminput frequency of 20 kHz.Minimum input frequency forproximity transducers is 0.0167Hz (1 rpm for 1 event/revolution)and for passive magnetic pickupsis 3.3 Hz.

Get A Quote
Contact Us

350050 BENTLY Description
The 3500/50 Tachometer Module is a 2-channel module that accepts input fromproximity probes or magnetic pickups (except as noted) to determine shaftrotative speed, rotoracceleration, or rotor direction, compares thesemeasurements against user-programmable alarm setpoints, and generatesalarms when these setpoints are violated. The 3500/50Tachometer Module is
programmed using the 3500 Rack Configuration Software and can beconfigured with four different options:
1. Speed Monitoring, Setpoint Alarming, and Speed Band Alarming.
2. Speed Monitoring, Setpoint Alarming, and Zero Speed Notification.
3. Speed Monitoring, Setpoint Alarming, and Rotor Acceleration Alarming.
4. Speed Monitoring, Setpoint Alarming, and Reverse Rotation Notification.
The 3500/50 can be configured to supply conditioned Keyphasor® signals to thebackplane of the 3500 rack for use by other monitors, thus eliminating the needfor a separate Keyphasor module in the rack. The 3500/50 also has a peak holdfeature that stores the highest speed, highest reverse speed, or number ofreverse rotations (depending on channel type selected) that the machine hasreached. These peak values can be reset by the user.

Speed Input:
The 3500 Tachometer will support0.0039 – 255 events per revolutionwith a maximum full scale rangeof 99,999 rpm and a maximuminput frequency of 20 kHz.Minimum input frequency forproximity transducers is 0.0167Hz (1 rpm for 1 event/revolution)and for passive magnetic pickupsis 3.3 Hz.

The 3500/50 Tachometer Module is a 2-channel module that accepts inputs from proximity probes or magnetic sensors (unless otherwise specified) to determine shaft speed, rotor acceleration, or rotor direction, compare these measurements with user programmable alarm setpoints, and generate alarms when these setpoints are violated.

Galil DMC-1000 1500 DMC-630 motion control board NEW

Galil DMC-1040 Motion Control Board NEW 1000

GE Fanuc A16B-1211-0890/​10A Power Supply Unit Refurb

Promess PPM Electronics 8500300103 monitor panel meter

Yaskawa Memocon-SC JAMSC-IF62A interface module RIOD

OTC Daihen CM-231 wire feeder feed welder welding NEW

Tags: ,