summary

Prol inx Modbus Plus to Modbus Master/Slave Gateway provides strong connectivity between devices on the Modbus Plus network and Modbus devices. This independent DIN rail mounted protocol gateway provides a Modbus Plus

The Modbus Plus protocol driver supports the master-slave implementation of the protocol on the DB9 mother Modbus Plus port, with up to four supporting Modbus power ports. The Modbus Plus port is fully configurable.

Get A Quote
Contact Us

5302-MBP-MCM4MB PROSOFT

summary

Prol inx Modbus Plus to Modbus Master/Slave Gateway provides strong connectivity between devices on the Modbus Plus network and Modbus devices. This independent DIN rail mounted protocol gateway provides a Modbus Plus

The Modbus Plus protocol driver supports the master-slave implementation of the protocol on the DB9 mother Modbus Plus port, with up to four supporting Modbus power ports. The Modbus Plus port is fully configurable.

The Modbus protocol driver supports both the master and slave implementations of the protocol. All Modbus serial ports can be individually configured to provide a very powerful and flexible host or device interface solution.

The MBP-MCM module is an ideal solution for many applications, where ModbusPlus connections can be used to integrate Modbus devices into the system. The Modbus Plus gateway is a powerful tool

The module supports both clients and servers, and can easily connect to Rockwell Automation, PLCS (CIXSLCPICCPIX and similar devices). Combined with Modbus device support, this module provides a very powerful interface for many ASCII devices used in the industrial market today.

The application of this module has been applied in most industries, especially manufacturing, oil and gas, electricity, and food processing. The specification internal database ProLinx module includes one

An internal database containing application data, status information, and configuration information regions. The internal libraries are shared among all ports on the module and used to transfer information from devices on one network to another network

A pipeline consisting of multiple devices, where the application data area and data area are stored and retrieved using a communication protocol driver, as well as data exchange between protocols. The database is used to write commands to remote devices and save data from remote devices

The source configuration file of the collected data (stored in the configuration data area) defines the external processing method of the command control data in the data library. The status data storage area is used to store error codes, counters, and port status information for each port

Breath. The Configuration Data area contains module configuration information, such as port configuration, network information, command configuration, etc.

Modbus Plus to Modbus Master/Slave 5301/5302-MBP-MCM (4) ProLinx Modbus Plus to Modbus Master/Slave Gateway establishes a strong connection between devices on the Modbus Plus network and Modbus devices. This independent DIN rail mounted protocol gateway provides one Modbus Plus port and up to four serial ports that support Modbus.