5X00489G01 EMERSON
Product Description
5X00489G01 | Emerson | Power distribution module
Multifunctional switch/measuring unit
6 slots, size C
Small size and low cost
Portable or rack mounted
Super reliable
The power supply can be serviced through the rear panel
Pressurized pipeline cooling
For complete and detailed information, click on the data table link.
For rack installation information, refer to the user manual.
Power distribution module
manufacturer
Emerson
Estimated shipping size
Size: 12.7 “x3.0” x2.8
(32.1 cm x 7.6cm x 7.0 cm)
Weight: 0lbs12.0oz (0.3kg)
0 configuration module. Module Configuration
(1=configured; 0=not configured)
1 Mandatory internal error. internal error
(1=mandatory error; 0=no mandatory error)
2-5 not used. Never used it before.
6 Enable digital input fuse signal and
Module attention to fuses.
Enable the status and
Module attention to fuses.
7 Not used. Should be set to zero (0). The digital input fuse has blown.
8-contact input field card (enable contact input
Auxiliary voltage 5X00489G01 fault signal and module
Pay attention to auxiliary voltage faults and
Ground fault detection circuit).
Contact Input Field Card Status (Enable Contact Input
Auxiliary voltage fault signal and module attention
For auxiliary voltage faults and ground faults
Detection circuit).
9 not used. Should be set to zero (0), contact input auxiliary voltage fault.
10. Enable the module to pay attention to GND faults. Enable the module to pay attention to the status of GND faults.
-Rshunt=contact shunt resistance
-Rcontact=Resistance related to the closed contact
-Rreturn=Resistance of the common return line
-Rline=Resistance of non-public cable length in and out of contacts
-Rwiring=Rcontact+Rline+16Rreturn
-Rfault=Resistance of any line to ground that causes a ground fault
Figure 21-5 shows the cable resistance 5X00489G01 that may affect contact input performance.
The following restrictions apply:
。 Under no ground fault conditions or if the channel return (low) line has
Ground fault:
-The Rshunt across contact must be ≥ 10k ohms to always recognize an open circuit
Contact is open.
-Rshunt across contact must be ≥ 50kohms to maintain high-level contact
Wetting voltage.
。 If there is a ground fault with open contacts in the input connection from the channel:
-Rshunt across contact must be ≥ 150kohms to ensure ground fault
Detected.