EMERSON+A6824 9199-00090

EMERSON+A6824 9199-00090

Under continuous thermal overload conditions, a temperature of 30°C produces a pulse output. Thermal overload protection is designed to protect the A6110 in case of failure. Do not exceed the maximum junction temperature rating TJ=125°C for absolute continuous operation. Built-in return current When the output voltage drops, the limit protection circuit will reduce the current value. When the output is short-circuited to the ground, the current limit is reduced to 250mA to avoid damage to the device.

EMERSON Module A6824 9199-00090 Emerson test card

A6220 A6410 A6824 A CMOs-based low voltage differential positive voltage regulator +2.5V to 6.0V. Output voltages are optional, ranging from 1.0V to 5.0V, providing up to 1.0A of current. Thermal protection Thermal overload protection limits When the total power consumption in the A6110 exceeds TJ=165°C, the OTP circuit activates the thermal shutdown function and shuts down the transfer element to allow the IC to cool. After the junction temperature of the IC is cooled, the OTP circuit re-opens the channel element.

Reviews

There are no reviews yet.

Be the first to review “EMERSON+A6824 9199-00090”

Your email address will not be published. Required fields are marked *