HIMA+F8652E

HIMA+F8652E

  • Module Type: Safety I/O Module
  • Bus Interface: Typically Profibus DP, Modbus, or HIMA’s proprietary protocols
  • Signal Inputs:
    • Digital Inputs: Typically 16 to 32 channels (could be binary, depending on the configuration)
    • Analog Inputs: May include 4-20mA or voltage signals, depending on the model
    • Input Types: Can include NAMUR sensors, dry contacts, and other typical industrial signal formats

Product Name:

HIMA F8652E Safety I/O Module

Product Description:

The HIMA F8652E is a safety I/O module designed for use in safety-critical applications, particularly in industries such as oil & gas, chemical processing, power generation, and other high-risk industrial environments. The module typically integrates into HIMA’s safety system architecture to manage and process safety-related I/O signals. It works within the framework of functional safety standards such as IEC 61508 and IEC 61511 and is part of HIMA’s overall solution for implementing SIL (Safety Integrity Level) rated functions.

Product Parameters and Specifications:

Here are typical parameters and specifications you may find for such modules:

  • Module Type: Safety I/O Module
  • Bus Interface: Typically Profibus DP, Modbus, or HIMA’s proprietary protocols
  • Signal Inputs:
    • Digital Inputs: Typically 16 to 32 channels (could be binary, depending on the configuration)
    • Analog Inputs: May include 4-20mA or voltage signals, depending on the model
    • Input Types: Can include NAMUR sensors, dry contacts, and other typical industrial signal formats
  • Signal Outputs:
    • Digital Outputs: Typically 16 to 32 channels, usually relay or transistor outputs
    • Analog Outputs: Depending on the configuration (e.g., 4-20mA)
  • Power Supply: Typically 24V DC (may vary depending on the specific product)
  • Temperature Range: Typically from -20°C to +60°C (may vary depending on environmental conditions)
  • Mounting: DIN rail mounting
  • Protection: IP20 or IP65 (depending on the configuration)
  • Standards Compliance:
    • IEC 61508 (SIL 3 capable)
    • IEC 61511
    • EN 61131-2 (for programmable logic controller (PLC) modules)
    • ATEX or other relevant safety certifications (if used in explosive environments)

Product Use:

The HIMA F8652E module is used in safety applications where reliable monitoring and control of process variables (temperature, pressure, flow, etc.) are required to ensure the protection of personnel, equipment, and the environment. Typical uses include:

  • Safety Instrumented Systems (SIS): For implementing safety functions such as Emergency Shutdown (ESD), Process Shutdown (PSD), and Fire and Gas Detection (F&G).
  • Industrial Automation: Used in combination with other HIMA systems to provide high-integrity safety monitoring for critical processes.
  • Oil & Gas: In offshore platforms, refineries, pipelines, etc., to ensure safety functions like pressure relief, gas leak detection, etc.
  • Chemical and Pharmaceutical: Ensuring process safety for high-risk processes like reactors, distillation columns, and tanks.
  • Power Generation: Critical for monitoring and controlling safety functions in nuclear, thermal, and renewable power plants.

HIMA+F8652E
GE IC610CHS110
IC610CHS130 GE PLC
IC610CHS134A GE
IC610CPU101C GE PLC
GE IC610CPU104 PLC
GE IC610MDL107B CPU
IC610MDL112A GE CPU
GE IC610MDL124A PLC
GE IC610MDL125A CPU
IC610MDL125B GE I/O
PRD-0064DC-40-00 KOLLMORGEN PLC
KOLLMORGEN PRD-P303250Z-35
PRD-P310250Z-55 KOLLMORGEN PLC
BJRL-20012-110001 KOLLMORGEN
CR06200-000000 KOLLMORGEN PLC
PRD-P320260Z-C2 KOLLMORGEN PLC
LE03565 KOLLMORGEN PLC
IC610MDL126A PLC
IC610MDL129A GE PLC
IC610MDL151 PLC

Reviews

There are no reviews yet.

Be the first to review “HIMA+F8652E”

Your email address will not be published. Required fields are marked *

Scroll to Top