PXI-6052E NI

National Instruments PXI-6052E (part numbers: 777962-01, 186408E-01) is a multifunctional DAQ with 16 channels and 16 bit resolution, and is a member of the fully functional E-series. This single slot PXI module has two analog outputs, analog/digital triggering, eight digital I/O lines, 15 analog input signal ranges, and two 24-bit counters/timers.

Get A Quote
Contact Us

PXI-6052E NI

National Instruments PXI-6052E(part numbers:777962-01,186408E-01)is a multifunctional DAQ with 16 channels and 16 bit resolution,and is a member of the fully functional E-series.This single slot PXI module has two analog outputs,analog/digital triggering,eight digital I/O lines,15 analog input signal ranges,and two 24-bit counters/timers.NI PXI-6052E provides real-time performance through LabVIEW and is fully compatible with other software packages/application development environments(ADEs),such as VI Logger,Measurement Studio,and Visual Basic,C#,and C/C++.This multifunctional DAQ can be configured and programmed using NI-DAQ 7 driver software.Using NI PXI-6052E,users need NI-DAQ,a computer,DAQ device,and LabVIEW or Measurement Studio(optional).

National Instruments PXI-6052E offers 16 single ended or 8 differential channels (with software options for each channel) and a maximum sampling rate of 333 kS per second. While operating with 20 V range selected, this model offers ±10 V bipolar input range. However, at 100 mV (minimum software selectable range), PXI-6052E provides a ± 50 mV bipolar input range and a 0 to 100 mV unipolar input range. In terms of its transmission characteristics, this model provides ± 1.5 (typical value) and ± 3 (maximum value) LSB. The DAQ is also equipped with a frequency scaler. The DC coupler has 6 trigger lines, 1 star trigger, and is equipped with 3 DMA channels.

 

The resolution of its counter/timer and frequency scalar is 24 bits and 4 bits respectively; They are compatible with 5 VTTL/CMOS. The recommended warm-up time for this multifunctional DAQ is 15 minutes. The calibration interval is one year. The NI PXI-6052E is equipped with a SCSI-II type 68 pin male SCSI-II I/O connector. The model also supports external inputs of 10 k Ω analog or digital triggers (PFI 0/AI START TRIG) with DC coupling. The device weighs 7.2 ounces and measures 6.3 x 3.9 inches. The recommended working temperature is 0 to 55 ° C and the storage temperature is -20 to 70 ° C. National Instruments has announced

National Instruments PXI-6052E (part numbers: 777962-01, 186408E-01) is a multifunctional DAQ with 16 channels and 16 bit resolution, and is a member of the fully functional E-series. This single slot PXI module has two analog outputs, analog/digital triggering, eight digital I/O lines, 15 analog input signal ranges, and two 24-bit counters/timers.

Tags: ,
Scroll to Top